Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cardiol Young ; 33(10): 1942-1949, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36408693

RESUMO

BACKGROUND: An interatrial communication is present in most neonates. The majority are considered the "normal" patency of the oval foramen, while a minority are abnormal atrial septal defects. Differentiation between the two with transthoracic echocardiography may be challenging, and no generally accepted method of classification is presently available. We aimed to develop and determine the reliability of a new classification of interatrial communications in newborns. METHODS AND RESULTS: An algorithm was developed based on echocardiographic criteria from 495 newborns (median age 11[8;13] days, 51.5% females). The algorithm defines three main categories: patency of the oval foramen, atrial septal defect, and no interatrial communication as well as several subtypes. We found an interatrial communication in 414 (83.6%) newborns. Of these, 386 (93.2%) were categorised as patency of the oval foramen and 28 (6.8%) as atrial septal defects.Echocardiograms from another 50 newborns (median age 11[8;13] days, 36.0% female), reviewed by eight experts in paediatric echocardiography, were used to assess the inter- and intraobserver variation of classification of interatrial communications into patency of the oval foramen and atrial septal defect, with and without the use of the algorithm. Review with the algorithm gave a substantial interobserver agreement (kappa = 0.66), and an almost perfect intraobserver agreement (kappa = 0.82). Without the use of the algorithm, the interobserver agreement between experienced paediatric cardiologists was low (kappa = 0.20). CONCLUSION: A new algorithm for echocardiographic classification of interatrial communications in newborns produced almost perfect intraobserver and substantial interobserver agreement. The algorithm may prove useful in both research and clinical practice.


Assuntos
Septo Interatrial , Forame Oval , Comunicação Interatrial , Criança , Humanos , Recém-Nascido , Feminino , Masculino , Reprodutibilidade dos Testes , Comunicação Interatrial/diagnóstico por imagem , Septo Interatrial/diagnóstico por imagem , Ecocardiografia
2.
J Am Soc Echocardiogr ; 32(7): 895-905.e2, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31076139

RESUMO

BACKGROUND: The Copenhagen Baby Heart Study (CBHS) is a population-based cohort study of neonates (N = 25,000), including echocardiography. Echocardiography in neonates is mainly focused on congenital heart disease (CHD), whereas general aspects of cardiac dimensions and function in neonates without CHD remain to be further addressed. PURPOSE: This study was conducted to assess the reliability of neonatal echocardiography and validity of echocardiographic methods used in the CBHS. METHODS: Reliability and agreement were tested for two-dimensional (2D), M-mode, spectral Doppler, and tissue velocity echocardiography for the following. (1) Measurements: seven sonographers independently performed two measurement rounds: (a) measurement of the same 50 echocardiograms (n = 350 echocardiograms measured) and (b) repeated measurement of 25 of the 50 echocardiograms (n = 175 echocardiograms measured). (2) Acquisition: four sonographers independently performed two rounds of echocardiographic acquisition and subsequent measurement of the same 22 neonates (n = 176 acquisitions and measures). Intra- and interobserver variabilities were assessed by determinations of coefficient of variation (CV), intraclass correlation coefficient (ICC), Bland-Altman plot, and 95% limits of agreement. RESULTS: (1) Measurements: we found intra- and interobserver ICC ≥ 0.67 for 2D parameters, except for left ventricular (LV) wall thicknesses and LV diameter (interobserver); ICC ≥ 0.84 for tricuspid annular plane systolic excursion (TAPSE); ICC ≥ 0.93 for pulsed-wave Doppler (PW); ICC ≥ 0.84 for continuous-wave Doppler; and ICC ≥ 0.87 for tissue velocity parameters. We found CV < 15% for all parameters except LV wall thicknesses. (2) Acquisition: we found intra- and interobserver ICC ≥ 0.69 for 2D parameters, except for LV wall thicknesses, aortic valve annulus (interobserver), and LV end-systolic diameter (interobserver); ICC = 0.45-0.49 for TAPSE; ICC = 0.48-0.64 for PW; and ICC ≥ 0.70 for continuous wave. We found CV < 15% for all parameters. CONCLUSIONS: Reliability of echocardiographic measurements and acquisition of cardiac dimensions and function were good for most parameters but lower for TAPSE (acquisition) and PW Doppler (acquisition) and poor for LV wall thicknesses. In general, echocardiography of cardiac dimensions and function in the neonate is reliable.


Assuntos
Ecocardiografia/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Dinamarca , Feminino , Humanos , Recém-Nascido , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...